Release Notes
- 2025-12-03
- 2025-11-20
- 2025-10-24
Branding Alignment
The Laboperator product is now available solely under the Laboperator branding, with no attachment to Labforward.
Introducing Workspace
Now Laboperator is Easier Than Ever!
Stay focused and get things done faster with quick access to all your tools and data in one place. No more jumping between dashboards or losing track of your work—everything you need is right where you need it.
With the new context-driven navigation, you can:
- Define your own context to organize work the way you want.
- Add resources like dashboards and workflows to keep everything connected.
- Access all connected tools instantly without leaving your current task.
- Switch between contexts seamlessly, so managing multiple projects feels effortless.
Work smarter, not harder—Laboperator keeps you in the flow.
- 2025-09-24
- 2025-09-09
- 2025-08-25
Driver Releases
driver-sicsserial v6.0.0
(AX26 - Mettler Toledo, MS-S/MS-L - Mettler Toledo, AB-S/PB-S - Mettler Toledo, MS-TS - Mettler Toledo, BBx46 - Mettler Toledo, XS - Mettler Toledo, XPE - Mettler Toledo, XPR - Mettler Toledo, AX205 - Mettler Toledo, XSE - Mettler Toledo, XP - Mettler Toledo, XSR (RS232) - Mettler Toledo, MX - Mettler Toledo)- Added:
- Calibration requests can be scheduled to happen at a certain time of the day and at a certain rhythm (using the cron syntax)
- Fixed:
- Screen freezes on older models no longer happen
- XPR balances no longer lose connection to LO after being reset
driver-sicstcp v3.0.0
(XPR (TCP) - Mettler Toledo, XSR (TCP) - Mettler Toledo)- Added:
- Calibration requests can be scheduled to happen at a certain time of the day and at a certain rhythm (using the cron syntax)
- Fixed:
- Screen freezes on older models no longer happen
- XPR balances no longer lose connection to LO after being reset
- Added:
- 2025-08-08
- 2025-07-28
- 2025-07-11
- 2025-07-02
- 2025-06-16
- 2025-06-02
- 2025-05-20
Driver Releases
driver-axis-camera v4.1.1
(IP Camera - Axis Communications)- Updated:
- Driver stability (libraries updated to the latest version)
driver-webcam v4.0.1
(Generic Webcam - labforward GmbH, C922 - Logitech)- Updated:
- The FPS value of the video is now 15 FPS by default
- New image quality options (“high” and “highest”) are now available
- Updated:
- 2025-05-13
- 2025-05-05
- 2025-04-25
- 2025-04-07
Driver Releases
driver-sartorius-sartocheck v1.0.0
(Sartocheck 5 - Sartorius)- Added:
- New device
driver-sila-client v2.6.0
(SiLA Client - labforward GmbH, Kevin - Fraunhofer IPA, Labeler - HTI, Spark - Tecan, Buddy - bAhead, Cedex Bio HT Analyser - Roche, Fluent - Tecan)- Removed:
- The “default” Dashboard has been removed, so that the generated Feature tabs are the first visible when opening a Dashboard.
- Added:
- 2025-03-26
- 2025-03-07
- 2025-02-24
- 2025-02-17
- 2025-02-12
Driver Releases
driver-sila-client v2.5.1
(SiLA Client - labforward GmbH, Kevin - Fraunhofer IPA, Labeler - HTI, Spark - Tecan, Buddy - bAhead, Cedex Bio HT Analyser - Roche, Fluent - Tecan)- Fixed:
- Bug where Commands without parameters could not be triggered anymore from Dashboards
driver-sicsserial v5.0.0
(AX26 - Mettler Toledo, MS-S/MS-L - Mettler Toledo, AB-S/PB-S - Mettler Toledo, MS-TS - Mettler Toledo, BBx46 - Mettler Toledo, XS - Mettler Toledo, XPE - Mettler Toledo, XPR - Mettler Toledo, AX205 - Mettler Toledo, XSE - Mettler Toledo, XP - Mettler Toledo, XSR (RS232) - Mettler Toledo, MX - Mettler Toledo)- Fixed:
- The driver works normally (ie, no TRANSFER key needed) with every device type.
- The screens of older models, including XP and XS, no longer freeze after a few hours of use.
- Fixed:
- 2025-01-29
- 2025-01-13
Driver Releases
driver-axis-camera v4.1.0
(IP Camera - Axis Communications)- Updated:
- Driver performances
driver-mt-sevenexcellence v2.0.0
(SevenExcellence - Mettler Toledo)- Updated:
- Driver stability & performances
- Fixed:
- Longer timeout duration for commands
driver-sila-client v2.5.0
(SiLA Client - labforward GmbH, Kevin - Fraunhofer IPA, Labeler - HTI, Spark - Tecan, Buddy - bAhead, Cedex Bio HT Analyser - Roche, Fluent - Tecan)- Updated:
- Default values for command parameters
- Fixed:
- Observable properties are subscribed to when reconnecting to a server
Bugfixes
This release focuses on fixing bugs and improvement to UX and stability:
- Device command error will now be marked as such in the audit trail
- Fix device locking/unlocking when the original owner of the device left the organization
- Dashboard's buttons will now be disabled when editing, to avoid miss-triggering of device command
- Fix issue with "Frequently Used Resource" filter being ignored in Saved Filters
- Updated:
- 2024-12-19
- 2024-12-18
Driver Releases
driver-heidolph-vap-ultimate v1.3.1
(Hei-VAP Ultimate Control - Heidolph)- Fixed:
- Loop setting restored. The device ping will no longer timeout if the loop duration is increased.
driver-mir-robot v1.1.2
(MiR250 - Mobile Industrial Robots)- Fixed:
- Driver Stability when the server throws errors
driver-axis-camera v4.0.0
(IP Camera - Axis Communications)- Added:
- Commands to create, edit and delete Preset Positions
- Command to move to any Preset Position
- Updated:
- User-friendly dashboard element to select Preset Positions
- Fixed:
- Driver Stability
- Fixed:
- 2024-12-02
Driver Releases
driver-anton-paar-dma v3.2.0
(DMA Series - Anton Paar)- Added:
- Measurement data is now accessible from the Command object
- Updated:
- Driver Stability
driver-axis-camera v3.3.0
(IP Camera - Axis Communications)- Updated:
- Driver Stability
- Fixed:
- New Preset Position set doesn’t affect the Home Position anymore
driver-mir-robot v1.1.1
(MIR250 - Mobile Industrial Robots)- Updated:
- Driver Stability
driver-sila-client v2.4.0
(SiLA Client - labforward GmbH, Kevin - Fraunhofer IPA, Labeler - HTI, Spark - Tecan, Buddy - bAhead, Cedex Bio HT Analyser - Roche, Fluent - Tecan)- Added:
- Connection to secure servers with certificate
- Updated:
- Driver Stability
- Added:
- 2024-11-19
- 2024-11-07
- 2024-10-24
- 2024-10-04
- 2024-09-24
- 2024-09-15
- 2024-09-06
- 2024-08-23
Driver Releases
driver-buechi-b545 v2.0.1
(B-545 - Büchi)- Fixed:
- Bug that would crash driver in Connector Box v.4.3 and above
driver-ika-eurostar v2.2.1
(EUROSTAR 60 Control, EUROSTAR 100 Control - IKA)- Fixed:
- Bug that would crash driver in Connector Box v.4.3 and above
driver-kern-abj v1.2.1
(ABJ-NM - Kern)- Fixed:
- Bug that would crash driver in Connector Box v.4.3 and above
driver-kern-plj v1.2.1
(PLJ-C - Kern)- Fixed:
- Bug that would crash driver in Connector Box v.4.3 and above
driver-mt-easydirect-ph v1.2.0
(SevenDirect - Mettler Toledo)- Changed:
- Default scope for dashboard data display set to 24 hours
- Additional instructions on dashboard
driver-mt-sevencompact v1.7.0
(SevenCompact - Mettler Toledo)- Changed:
- Default scope for dashboard data display set to 24 hours
driver-presens-eom v2.2.1
(EOM PH LG1 MIni - PreSens)- Fixed:
- Bug that would crash driver in Connector Box v.4.3 and above
driver-radwag v1.2.1
(R Series - Radwag)- Fixed:
- Bug that would crash driver in Connector Box v.4.3 and above
driver-sartoriusbalance v1.2.1
(CP/GC/GP, Extend Series, Entris Series - Sartorius)- Fixed:
- Bug that would crash driver in Connector Box v.4.3 and above
driver-sentron-si v1.3.0
(SI600 - Sentron)- Changed:
- Default scope for dashboard data display set to 24 hours
driver-sevenstar-mfc v1.2.1
(D08 series- SEVENSTAR)- Fixed:
- Bug that would crash driver in Connector Box v.4.3 and above
driver-sh-autodosage v3.0.1
(Autodosage - S+H)- Fixed:
- Bug that would crash driver in Connector Box v.4.3 and above
driver-waldner-ac3 v1.2.1
(AC3 - WALDNER)- Fixed:
- Bug that would crash driver in Connector Box v.4.3 and above
driver-yudian-ai v1.2.1
(AI Series - Yudian)- Fixed:
- Bug that would crash driver in Connector Box v.4.3 and above
driver-yudian-ai-719 v1.2.1
(AI-719- Yudian)- Fixed:
- Bug that would crash driver in Connector Box v.4.3 and above
Various bugfixes
This release focus on fixing many bugs that has been reported by our users. Including:
- User configured preferred timezone will be respected in all display of date and time
- Fix display of dynamic thresholds in line chart when custom scope are chosen
- Fix display of the value
0in DeviceChannel element in dashboard - Allow driver to upload file larger than 4MB, with a maximum of roughly 15MB
- Fix tracking of device usage when command are being sent directly from the device's dashboard
- Fixed:
- 2024-08-09
Driver Releases
115 drivers have been updated to the latest dependencies, to fix a memory leak issue and improve stability.
driver-axis-camera v3.2.0
(IP Camera - Axis Communications)- Updated:
- Improved stability of device status and subsequently camera stream
driver-anton-paar-dma v3.1.1
(DMA Series - Anton Paar)- Fixed:
- Bug that prevented new instances of the device to be added
driver-biotage-initiator v2.0.0
(Initiator<ins> - Biotage)- Updated:
- Renamed Command parameter to fit naming conventions
driver-biotage-isolera v2.0.0
(Isolera One - Biotage)- Updated:
- Renamed Command parameter to fit naming conventions
driver-biotage-selekt v3.0.0
(Selekt - Biotage)- Fixed:
- Typo in Channel name
driver-buechi-b545 v2.0.0
(B-545 - Büchi)- Updated:
- Renamed Commands to fit naming conventions
driver-esco-mixer v2.0.0
(Mixer 50 - Esco-Labor)- Updated:
- Renamed driver setting “clientId” into “deviceId”
- Loop logic (offline state is now OFF, not ERROR)
- Fixed:
- Incorrect serial driver settings names
driver-hirschmann-opus v3.0.0
(Opus - Hirschmann)- Updated:
- Renamed Channels and Commands to fit naming conventions
driver-ika-rctdigital v5.3.0
(RCT Digital - IKA, RCT Digital (Dual-Operation), IKA)- Fixed:
- Viscosity Channel range no longer limited between 0 and 100%
driver-iuta-sensor-array v2.0.0
(Sensor Array - IUTA)- Updated:
- Renamed Channels to fit naming conventions
driver-liconic-stx v1.4.0
(STX44 - LiCONiC)- Updated:
- Data points are only created when Channels have a new value
driver-kds-legato v2.0.0
(Legato 100 - KD Scientific)- Updated:
- Renamed Commands to fit naming conventions
driver-modbus-console v2.0.0
(Modbus Console (Serial), Modbus Console (TCP) - labforward GmbH)- Updated:
- Renamed driver setting “clientId” into “deviceId”
- Fixed:
- Incorrect serial driver settings names
driver-serialconsole v3.0.0
(Serial Console - labforward GmbH)- Updated:
- Renamed Commands to fit naming conventions
driver-sh-autodosage v3.0.0
(Autodosage - S</ins>H)- Updated:
- Renamed Commands to fit naming conventions
driver-smartlab-uart-shield v2.0.0
(UART Shield - SmartLabs Solutions)- Updated:
- Renamed Command parameter to fit naming conventions
driver-system-health v1.6.0
(System Health Monitor - labforward GmbH)- Added:
- Command to download Connector Box logs
driver-tecan-cavro-xlp v2.0.0
(Cavro XLP - Tecan)- Fixed:
- Duplicate Commands in definition
driver-techman-robotarm v2.0.0
(Robot Arm - Techman)- Updated:
- Renamed Command parameter to fit naming conventions
driver-vacuubrand-vacuuselect-modbus v2.0.0
(VACUU-SELECT (TCP) - Vacuubrand)- Updated:
- Renamed driver setting “clientId” into “deviceId”
- Updated:
- 2024-08-01
- 2024-07-31
- 2024-07-29